Standards • IEC 34 - IEC 72 |
|
Insulation • Class H |
|
Balance • IEC 34-14 grade 'N' standard • Grade 'R' on request |
|
Temperature rise • Class F |
|
Overload capacity • 1.8 x FLC for 15 seconds every 5 minutes • 1.8 x FLC for 30 seconds every 30 minutes |
|
Terminal box position • Standard: On top of the motor • Mounting of terminal box on either side on request |
|
Blower position • Standard: On top of the motor non-drive end • Other positions on request • Blower is supplied without filter as standard • Filter on request |
|
Bearings • Grease lubricated ball bearings as standard • For belt drive please contact our sales offices |
|
Heat exchangers - Air/water (IC 86W): • Air/water exchangers are especially recommended for polluted environment • Standard is for clean water • For corrosive water on request • Position on top of motor as standard • Fan motor at D-end • Water connection flanges at right hand side (facing D-end) • Max water pressure 10 PSI • Max inlet water temperature 25°C • A water temperature rise of 8-10°C must be expected • For motors with low loads or a low incoming water temperature, a temperature regulator a temperature regulator is recommended to avoid condensation in the cooling air cicuit and to minimize water consumption • A constant speed fan ciculates the internal cooling air. A polyamide filter is provided for carbon dust |
|
Heat exchangers - Air/air (IC 666): • Air/air exchangers are recommended where water is not available for cooling purposes • The output of a motor with air/air exchanger will be approximately 20% lower compared to cooling forms IC06/17/37/86W |
| Frame | Supply voltage, frequency Y (V) | Current Y (A) | Supply voltage, frequency D (V) | Current D (A) | Power (kW) | Weight (kg) |
| DMP 112 DMP 132-2M DMP 132-4S/M/L |
3x380-420V 50Hz 3x440-480V 60Hz 3x500V 50Hz |
0.70 0.70 0.60 |
3x220-240V 50Hz 3x250-280V 60Hz |
1.20 1.20 |
0.25 0.30 0.25 |
7 |
| DMP 132-4LB DMP 160-4S/M/L |
3x380-420V 50Hz 3x440-480V 60Hz 3x500V 50Hz |
2.10 2.00 1.40 |
3x220-240V 50Hz 3x250-280V 60Hz |
3.60 3.50 |
0.75 0.90 0.75 |
16 |
| DMP 160-4LB |
3x380-420V 50Hz 3x440-480V 60Hz 3x500V 50Hz |
2.90 2.80 2.30 |
3x220-240V 50Hz 3x250-280V 60Hz |
5.00 5.00 |
1.30 1.50 1.30 |
18 |
| DMP 180-4A/B/C/D |
3x380-420V 50Hz 3x440-480V 60Hz 3x500V 50Hz |
3.00 2.90 2.70 |
3x220-240V 50Hz 3x250-280V 60Hz |
5.20 5.00 |
1.50 1.75 1.50 |
18 |
| DMP 180-4E/F |
3x380-420V 50Hz 3x440-480V 60Hz 3x500V 50Hz |
5.80 5.80 4.60 |
3x220-240V 50Hz 3x250-280V 60Hz |
10.0 10.0 |
2.70 3.00 2.70 |
20 |
| Frame | Drive End | Non-drive End | |
| Ball Bearing | Roller Bearing | Roller Bearing | |
| DMP 112 | 6308-C3 | NU 308 ECP | 6208-2RS 1-HT-C3 |
| DMP 132 | 6309-C3 | NU 309 ECP | 6307-2RS 1-HT-C3 |
| DMP 160 | 6310-C3 | NU 310 ECP | 6309-2RS 1-HT-C3 |
| DMP 180-4A/B/C/D/E | 6215-C3 | NU 2215 ECP | 6312-2RS 1-HT-C3 |
| DMP 180-4F | 6315-C3 | NU 315 ECP | 6312-2RS 1-HT-C3 |
![]() |
![]() |
![]() |
| Back | Next | Top of page |